Skip to content

Hanus_cntlr2.m

Basic Information

  SYNTAX:   [AH,BH,CH,DH] = Hanus_cntlr2(Ac,Bc,Cc,Dc,refcols,meascols)

  PURPOSE:  Convert controller to Hanus conditioned controller. This
     provides a means to eliminate anti-windup when output of the controller
     is limited in a known or measurable manner (e.g. by saturation).
     Constructed controller contains extra inputs for the signals representing
     the limited controller output.

     This version is different from the original in that inputs keep their
     same order.

  INPUT:
    Ac,Bc,Cc,Dc = controller to convert - either digital or continuous
    refcols = columns of input matrices (Bc,Dc) corresp. to references
    meascols = columns of input matrices (Bc,Dc) corresp. to measurements

  OUTPUT:
    AH,BH,CH,DH = Hanus controller

  RESTRICTIONS:  This function only works on controllers Ac,Bc,Cc,Dc which
     feed references and measurements into controller separately. (I.e. NOT
     error feedback controllers.)  Also, although theory predicts resulting
     controller should work for both continous and discrete controllers, I've
     only been able to make it work for discrete.

  METHOD:  See R.Hanus, M.Kinnaert, J.L.Henrotte, "Conditioning Technique,
  a General Anti-Windup and Bumpless Transfer Method", Automatica, v.23, no.6,
  pp. 729-739,1987