calc_PCS_PID_response.m
SYNTAX: PIDsys = calc_PCS_PID_response(dt,Gp,Gd,Gi,taup,taud,taui)
PURPOSE: Compute (digital) frequency response of PCS PID implementation.
(Response is nearly, but not quite, independent of dt - for dt
small enough. Put in a reasonable approximate value.)
INPUT:
dt = sample time
Gp = proportional gain
Gd = derivative gain
Gi = integral gain
taup = proportional time constant (sec)
taud = derivative time constant (sec)
taui = integral time constant (sec)
OUTPUT:
PIDsys = digital transfer function model of PID algorithm
(control toolbox packed format)
Dependencies