setup_plasma_sim.m

Basic Information

  SYNTAX:  setup_plasma_sim

  PURPOSE:  Define variables needed for simulink models that include plasma.

    Also defines some data that can be used to program the PCS when
    running in closed loop versus a simserver constructed from simulink
    model.  (Only works for EAST and KSTAR right now.)

  INPUT:
    vacuum_objs = vacuum model data structure
    iplcirc = set equal to 1 to include plasma circuit eqn in model
    ichooseq = choose type of equilibrium data to use:
                 0 = vacuum model (no plasma equilibrium required)
                 1 = efit gfile
                 2 = Corsica equilibrium files
                 3 = saved corsica equilibrium
                 4 = TokSys equilibrium data structure
    efit_gfile = EFIT equilibrium file (g-file), only needed if ichooseq=1
    corsica_inputs = name of ???
                       (required only if ichooseq=2)
    corsica_savefile = name of saved corsica equilibrium
                       (required only if ichooseq=3)
    equil_data = name of TokSys format equilibrium data structure
                       (required only if ichooseq=4)
    ip_init  = initial value for Ip
    dt_rz      = time step for R and Z feedback control
    Gp_z,Gd_z,Gi_z = gains for Z control
    taup_z,taud_z,taui_z = time constants for Z control
    Gp_r,Gd_r,Gi_r  = gains for R control
    taup_r,taud_r,taui_r = time constants for R control
    Vlimits_PF = upper and lower bounds on PF coil voltages
    idx_vcntl_ckts = indices of vertical control circuits in system model

  OUTPUT:
    many variables needed to initialize simulink (*.mdl) models
    Ip_gains = gain vector that can be used for Ip control in PCS
    FILES:
      <tokamak>_PCS_mutuals.dat = matrices needed by PCS to compute V trajs
      init_currents.dat = initial currents file (set = equilibrium values)

  RESTRICTIONS:
  (1) Assumes that first 3 sets of diagnostics are: coils, flux loops, probes
  (2) Works only when ohmic distribution currents all the same sign right now.
  (3) Does not work (incorrect diags_0) with nonzero equilibrium vessel currents.

Dependencies