setup_plasma_sim.m
SYNTAX: setup_plasma_sim
PURPOSE: Define variables needed for simulink models that include plasma.
Also defines some data that can be used to program the PCS when
running in closed loop versus a simserver constructed from simulink
model. (Only works for EAST and KSTAR right now.)
INPUT:
vacuum_objs = vacuum model data structure
iplcirc = set equal to 1 to include plasma circuit eqn in model
ichooseq = choose type of equilibrium data to use:
0 = vacuum model (no plasma equilibrium required)
1 = efit gfile
2 = Corsica equilibrium files
3 = saved corsica equilibrium
4 = TokSys equilibrium data structure
efit_gfile = EFIT equilibrium file (g-file), only needed if ichooseq=1
corsica_inputs = name of ???
(required only if ichooseq=2)
corsica_savefile = name of saved corsica equilibrium
(required only if ichooseq=3)
equil_data = name of TokSys format equilibrium data structure
(required only if ichooseq=4)
ip_init = initial value for Ip
dt_rz = time step for R and Z feedback control
Gp_z,Gd_z,Gi_z = gains for Z control
taup_z,taud_z,taui_z = time constants for Z control
Gp_r,Gd_r,Gi_r = gains for R control
taup_r,taud_r,taui_r = time constants for R control
Vlimits_PF = upper and lower bounds on PF coil voltages
idx_vcntl_ckts = indices of vertical control circuits in system model
OUTPUT:
many variables needed to initialize simulink (*.mdl) models
Ip_gains = gain vector that can be used for Ip control in PCS
FILES:
<tokamak>_PCS_mutuals.dat = matrices needed by PCS to compute V trajs
init_currents.dat = initial currents file (set = equilibrium values)
RESTRICTIONS:
(1) Assumes that first 3 sets of diagnostics are: coils, flux loops, probes
(2) Works only when ohmic distribution currents all the same sign right now.
(3) Does not work (incorrect diags_0) with nonzero equilibrium vessel currents.
Dependencies