Skip to content

calc_ohmic_res.m

Basic Information

  PURPOSE: Calculates Best Coil resistances to produce constant flux decay

  USAGE:  rcc= calc_ohmic_res(mcc,icc);

  INPUTS: [default]

     mcc=      coil mutual inductance matrix
     icc=   Optimum initial magnetization current vector

  OUTPUTS:

     rcc =   optimum resistance matrix

  METHOD:
     [I]^-1 is diaganal matrix made up of 1/I_i currents
     R/gamma =  [I]^-1 [M] I

 LIMITATIONS:
    Assumes the initial current distrubution is Ohmic (i.e. produces constant
            flux plateau in plasma region.
            icc is typically generated using ohmic_dist

    see also ohmic_dist.m

Dependencies