mutind_fine.m
SYNTAX: mutuals=mutind_fine(acoil_data,bcoil_data, ...
nrecta,nrectb,verbose)
PURPOSE: Compute mutual inductance between 2 sets of axisymmetric
conductors, each of whose cross-section is a parallelogram. Filament
conductors (identified by setting dR=dZ=0 in bcoil_data) are allowed
for conductor set B.
INPUT:
acoil_data = data describing geometry of coil set A
bcoil_data = data describing geometry of coil set B
Format of this data has each column = [Z;R;dZ;dR;AC;AC2], where:
Z = z centroids of conductors (m)
R = r centroids of conductors (m)
dZ = height of conductors (m)
dR = width of conductors (m)
AC = angle between coil and horizontal (degrees)
AC2 = angle between coil and horizontal (degrees)
At most one of AC, AC2 is nonzero and indicates type of parallelogram:
xxxx
xxxx x
xxxx x
xxxx x --- xxxxxxxxxxxxx
xxxx x | xx xx
--- xxxx x | xx xx
| x X xxxx dZ xx xx
| x (R,Z) xxxx | xx X xx
dZ x xxxx | xx (R,Z) xx
| x xxxx | xx xx
| x xxxx | xx xx
_|_ xxxx ^ --- xxxxxxxxxxxxx ^
AC ) AC2 )
|----------dR----------| |---dR------|
nrecta = rectangle partitioning for conductor set A (see header
documentation for bld_subelements.m)
nrectb = rectangle partitioning for conductor set B (see header
documentation for bld_subelements.m)
verbose = print/display verbose info. 0 = no print/display. Numbers>0
give increasingly more information/displays.
OUTPUT:
mutuals = mutual inductance matrix, with rows corresponding to coil
set A, columns to coil set B (micro-Henries)
RESTRICTIONS:
METHOD: Each conductor is partitioned into a bunch of tiny rectangles. All
mutuals are computed for these rectangles, then combined at the end.
Mutuals calculation is done in 2 steps:
(1) use filament to filament calculation for all subelements
(2) replace those subelement calculations which would have inaccurate
results, based on geometric information, with more accurate calculation.
Dependencies