Hanus_cntlr_rev1.m

Basic Information

  SYNTAX: [AH,BH,CH,DH,Cr,Dr,D1inv] = Hanus_cntlr(Ac,Bc,Cc,Dc,rcols,mcols,scols)

  PURPOSE:  Convert controller to Hanus conditioned controller. This
     provides a means to eliminate anti-windup when output of the controller
     is limited in a known or measurable manner (e.g. by saturation).
     Constructed controller contains extra inputs for the signals representing
     the limited controller output.

  INPUT:
    Ac,Bc,Cc,Dc = controller to convert - either digital or continuous
    rcols = columns of input matrices (Bc,Dc) corresp. to references
    mcols = columns of input matrices (Bc,Dc) corresp. to measurements
    scols = columns of input matrices (Bc,Dc) corresp. to chosen subblock
            (scols must = first noutputs columns of Dc, where
                    noutputs = number of outputs)

  OUTPUT:
    AH,BH,CH,DH = Hanus controller system description
    Cr,Dr       = output matrices which compute realizable reference
            (realizable ref.= Cr*[cntlr state] + Dr*[cntlr inputs]

   Note: no matter where reference signal comes into input controller, Hanus
   controller arranges inputs as [measurements, references, limited outputs]

  RESTRICTIONS:
    This version is experimental.  It inverts a square subblock of the full
    D matrix chosen by the user.  Explain why somewhere....
    Right now, only works for Dc which has more columns than rows, and
    scols must be first set of colums in Dc.

     This function only works on controllers Ac,Bc,Cc,Dc which
     feed references and measurements into controller separately. (I.e. NOT
     error feedback controllers.)  Also, although theory predicts resulting
     controller should work for both continous and discrete controllers, I've
     only been able to make it work for discrete.

  METHOD:  See R.Hanus, M.Kinnaert, J.L.Henrotte, "Conditioning Technique,
  a General Anti-Windup and Bumpless Transfer Method", Automatica, v.23, no.6,
  pp. 729-739,1987

Dependencies