calc_ssop_from_I.m
SYNTAX: ssop = calc_ssop_from_I(tok_system,ssop_inputs)
PURPOSE: Compute steady-state operating point (ynom,Inom,Vnom), where Inom contains
closest approximation to Icnom consistent with being a valid steady- state operating
point. Values of ynom are always nonzero when default values of zero nominal
currents are used.
INPUT:
tok_system = tokamak system model, as constructed by build_tokamak_system
ssop_inputs = structure containing all optional inputs:
Icnom = vector of PF coil currents defining center of coordinates for model. To use
plasma equilibrium currents, let Icnom = Pcc*Ieq(1:ncx) (optional, default = all 0)
Ipnom = value of plasma current defining center of coordinates for model (optional,
default = 0). Nonzero value should be used only if non-ohmic drive is available to
hold plasma current = Ipnom in steady-state.
OUTPUT:
ssop = steady state operating point, containing:
ynom = nominal values for outputs y
Inom = vector of nominal coil, vessel, and plasma currents (coil currents in
Inom are best match to Icnom that is consistent with steady-state gain)
Vnom = vector of voltages that produce coil currents in Inom vector
Inomstates = vector of nominal coil, vessel, and plasma current states
RESTRICTIONS: Only works right now for outputs that are modeled as linear relative to a
plasma equilibrium.
METHOD: See Prop. 3 of Walker & Humphreys, Valid Coordinate Systems for Linearized Plasma
Shape Response Models in Tokamaks (where it is shown that the only valid choice for
nominal vessel currents is 0). The Icnom vector is projected onto the range of the
steady-state gain to compute Inom; the pseudo-inverse of steady-state gain is applied
to compute Vnom (this is true inverse for vectors in range of steady-state gain).