Skip to content

bgreens_distrib.m

Basic Information

  SYNTAX: [brgreens,bzgreens,bpgreens] = ...
        bgreens_distrib(coil_data,bprobe_data,nrect,verbose)

  PURPOSE:  Compute Greens functions from axisymmetric current carrying
    conductors, each of whose cross-section is a parallelogram, to Br,
    Bz, and angled probe measurement at a set of specified points.
    (Use mutind_distrib with bcoil_data = filaments to compute Greens
    functions for flux.)  Can be used to compute Br,Bz Greens functions
    for arbitrary points in space.

  INPUT:
    coil_data = data describing geometry of coil set
       Format of this data has each column = [Z;R;dZ;dR;AC;AC2], where:
        Z   = z centroids of conductors (m)
        R   = r centroids of conductors (m)
        dZ  = height of conductors (m)
        dR  = width of conductors (m)
        AC  = angle between coil and horizontal (degrees)
        AC2 = angle between coil and horizontal (degrees)
    At most one of AC, AC2 is nonzero and indicates type of parallelogram:
                                xxxx
                            xxxx   x
                        xxxx       x
                    xxxx           x       ---                 xxxxxxxxxxxxx
                xxxx               x        |                xx         xx
       ---  xxxx                   x        |              xx         xx
        |   x          X        xxxx      dZ             xx         xx
        |   x        (R,Z)  xxxx            |          xx   X     xx
      dZ    x           xxxx                |        xx   (R,Z) xx
        |   x       xxxx                    |      xx         xx
        |   x   xxxx                        |     xx         xx
       _|_  xxxx   ^                       --- xxxxxxxxxxxxx    ^
                 AC )                                        AC2  )
            |----------dR----------|           |---dR------|

    bprobe_data  = Bprobe data, 5 x number of probes (or any msmnt pts):
        bpdata(1:5,:)=[Z;R;Ang;length(m);Ip coeff]
        (5th row is ignored, so 4 x number probes also works)
    nrect = rectangle partitioning for conductor set (see header
        documentation for bld_subelements.m)
    verbose = print/display verbose info.  0 = no print/display.  Numbers>0
        give increasingly more information/displays.

  OUTPUT:
    brgreens = Br Greens function matrix, with rows corresponding to probes,
        columns to conductors (Tesla/MA)
    bzgreens = Bz Greens function matrix, with rows corresponding to probes,
        columns to conductors (Tesla/MA)
    bpgreens = Greens function matrix to field measured by bprobes, with
        rows corresponding to probes, columns to conductors (Tesla/MA)

  RESTRICTIONS:

  METHOD:  Each conductor is partitioned into a bunch of tiny rectangles.  All
    bgreens are computed for these rectangles, then combined at the end.
    Calculation is done in 2 steps:
    (1) use filament to filament calculation for all subelements
    (2) replace those subelement calculations which would have inaccurate
    results, based on geometric information, with more accurate calculation.

Dependencies