Skip to content

Hanus_cntlr.m

Basic Information

  SYNTAX: [AH,BH,CH,DH,Cr,Dr,Dinv] = Hanus_cntlr(Ac,Bc,Cc,Dc,refcols,meascols)

  PURPOSE:  Convert controller to Hanus conditioned controller. This
     provides a means to eliminate anti-windup when output of the controller
     is limited in a known or measurable manner (e.g. by saturation).
     Constructed controller contains extra inputs for the signals representing
     the limited controller output.

  INPUT:
    Ac,Bc,Cc,Dc = controller to convert - either digital or continuous
    refcols = columns of input matrices (Bc,Dc) corresp. to references
    meascols = columns of input matrices (Bc,Dc) corresp. to measurements

  OUTPUT:
    AH,BH,CH,DH = Hanus controller system description
    Cr,Dr       = output matrices which compute realizable reference
            (realizable ref.= Cr*[cntlr state] + Dr*[cntlr inputs]

   Note: no matter where reference signal comes into input controller, Hanus
   controller arranges inputs as [measurements, references, limited outputs]

  RESTRICTIONS:  This function only works on controllers Ac,Bc,Cc,Dc which
     feed references and measurements into controller separately. (I.e. NOT
     error feedback controllers.)  Also, although theory predicts resulting
     controller should work for both continous and discrete controllers, I've
     only been able to make it work for discrete.

  METHOD:  See R.Hanus, M.Kinnaert, J.L.Henrotte, "Conditioning Technique,
  a General Anti-Windup and Bumpless Transfer Method", Automatica, v.23, no.6,
  pp. 729-739,1987

Dependencies