compare_system_outputs.m
SYNTAX: compare_system_outputs
PURPOSE: Compare outputs of generic-constructed system model with measured
signals that correspond to these outputs. This script builds the model, simulates
system outputs (driven by measurements) and compares those simulations with measured data.
INPUT (see build_<tokamak>_sys help for additional inputs):
tokamak = name of tokamak (e.g. 'd3d', 'kstar', 'nstx', ...)
config_name = string defining model configuration
ichooseq = see input to build_tokamak_system.m (ichooseq=0 => vacuum model)
model_shotnum = shot number to derive model from (only required if ichooseq > 0)
equil_time = time of plasma equilibrium in sec (only required if ichooseq > 0)
efit_source = source of mdsplus efit (only required if ichooseq = 4)
data_shotnum = number of shot to get data for model comparison
tmin, tmax = min and max times (sec) for data window
out_signals_col = index of column in output_signals array to define measured data
to compare against
output_index = indices of model outputs to compare model and data (coil currents are always included)
input_index = indices of model inputs (coil circuits) that are connected to power supplies (default = all)
output_index = defines which outputs to look at (default = all)
get_data_fn_input = string defining function to call when fetching input signals
get_data_fn_output = string defining function to call when fetching output signals
model_type = 1 for coil current inputs, 0 for voltage inputs (default = 0)
iplcirc = set to 1 to include plasma current circuit, else 0 (default 1, only needed if ichooseq>0)
first_time = set to 1 first time this script used (optional, default=1)
equil_avg_time = [sec] window over which to avg ptname data used
to calculate nominal equilibrium (optional, default=10ms)
cutoff = cutoff frequency (in Hz) to filter signals when plotting
ohstates_idx = index of coils to use to ramp in coil nominal trajectories for Ip drive
OUTPUT: comparison plots for model versus data.